Calculate the Inverter-UPS Size with Battery Bank(Excel Speardsheet)


Sizing an Inverter-UPS (Uninterruptible Power Supply) with a battery bank involves determining the appropriate capacity for both the inverter and the battery to ensure reliable backup power for your specific needs. This is crucial for maintaining uninterrupted power in case of mains power failures. Here's how you can calculate the size of an Inverter-UPS with a battery bank:

  1. Load Analysis:

    • Begin by conducting a thorough analysis of your electrical load. Determine the total power consumption of all devices you want to power during an outage. This includes essential equipment like computers, lighting, appliances, and any other critical loads.
  2. Load Type and Power Factor:

    • Consider the type of loads you have. Some loads, such as motors, may have high starting currents (inrush current), which should be factored into the sizing.
    • Account for the power factor of your loads. The power factor affects the apparent power, and the inverter must be sized to handle both real and reactive power.
  3. Backup Time:

    • Decide how long you need the backup power to last during an outage. This will determine the battery capacity required. Generally, the longer the backup time, the larger the battery bank needed.
  4. Inverter Size:

    • The inverter size is based on the total load capacity you wish to support. It should be able to handle the peak load, including any inrush currents.
    • Ensure that the inverter can provide a clean and stable power supply. Look for features like pure sine wave output to support sensitive electronic devices.
  5. Battery Capacity:

    • Calculate the battery capacity required using the formula: Battery Capacity (Ah) = Load (W) x Backup Time (hours) / Battery Voltage (V).
    • Choose the battery voltage based on the inverter's requirements and commonly available options, such as 12V or 24V batteries.
    • Be sure to select reliable, deep-cycle batteries suitable for frequent discharging and recharging cycles.
  6. Redundancy and Scalability:

    • Consider whether you need redundancy or scalability. Redundancy involves having multiple battery banks or inverters to ensure reliability, while scalability allows for expanding the system as needed.
  7. Inverter Efficiency:

    • Take into account the efficiency of the inverter. Inverters are not 100% efficient, so consider the losses in the conversion process when sizing the system.
  8. Charger Capacity:

    • If your Inverter-UPS includes a built-in battery charger (common in most UPS systems), ensure it can efficiently recharge the battery bank within an acceptable time frame.
  9. Safety and Maintenance:

    • Consider safety features and maintenance requirements of the system, such as battery maintenance, ventilation, and safety shutdowns in case of overloads or faults.
  10. Professional Advice:

    • For complex installations, consult with a professional in the field of power systems or electrical engineering to ensure the system meets your specific needs and local electrical regulations.

Sizing an Inverter-UPS with a battery bank is a critical task to ensure that your critical loads receive uninterrupted power during outages. It's important to carefully evaluate your load requirements and consider factors such as battery capacity, inverter size, and efficiency to design a reliable and efficient backup power system.